The Noise-Sentry-RT-Whas four modes of operation:
Mode |
Operation |
Power Consumption |
---|---|---|
Idle |
Disconnected from USB and not actively recording - Only keeps time. |
Minimal: can stay on for up to 6 months. |
Active |
Connected to USB – Not recording – Instrument is fully on and measuring |
Instrument draws power from USB to power itself, and if necessary recharge its battery. Battery is not depleted. |
Recording |
USB-connected or not - Fully on and recording. |
If USB-connected, power comes from USB. If not, power comes from the battery. If not connected the instrument can record for up to 7 days. |
Periodic WiFi™ Connect |
From any state, including Idle and Recording, the instrument can periodically wake up its WiFi™ interface and attempt to connect to a server. If the connection is not established after 1 minute it falls back to its original state until the next connection time. |
If USB-connected, power comes from USB. If not, power comes from the battery. The Periodic Connect feature consumes battery. This is especially the case if the connection interval is set to be short so it occurs often. |
Table 1